ISO 14644-1
covers the classification of air cleanliness in clean rooms, surgical
rooms and other controlled environments.
Classification
of Air Quality (particle counting), according to the ISO 14644-1 is a
valuable tool that guides the human team that is involved in controlling nosocomial infection.
Our work
methodology is based on the determination of basic parameters that ensure
the quality of air, for the prevention and control of infections transmitted
by the hospital environment.
Based in spanish
standard PNE 171340: Validation
and qualification.
Ccontrolled
environment rooms
More details...
|
|
The
Evidence (Validation) are achieved through a series of tests are performed
in these facilities:
-
Consulting design
phase.
-
Integrity and leak testing of filters.
-
No particle
counting.
-
ISO 14644-1 Classification.
-
Renovations-hour
calculation.
-
Calculating differential pressures.
-
Measurement Tp.
and relative
humidity.
-
Microbiological
testing environment.
-
Noise
and lighting.
|
|

Sick
building syndrome (SBS) is a term that was used since the mid-80s to
describe situations in which the occupants of the buildings are experiencing
acute problems associated with the time spent in these buildings. Symptoms
can include headache, dry cough, itching, vertigo, nausea and irritation of
eyes, nose and throat.
The
Innovate Indoor Air Quality (IAQ) - is a conceptual and operational
progress, comprehensive, modern and complex as to assume the risks and
solutions in indoor air . Exceed the concept of sick building, to define
healthy environments and goes beyond the idea of limiting the indoor air
as the only contaminant source.
More details...
|
-
LIPOATROPHIA SEMICIRCULARIS
STUDIES
Lipoatrophia
semicircularis (LS) related to the Buildings is clinically, in a
semicircle area of atrophy of the subcutaneous adipose tissue.
The cause is
directly related to modern office buildings and new work environments. SEGLA
specializes in studies of indoor environments for the prevention of diseases
related to new work environments - Lipoatrophia semicircularis
More details |
-
TRAINING INDOOR AIR QUALITY IN: SURGICAL ROOMS, CRITICAL AREES, AND LABORATORIES.
Our courses on
indoor air Quality in surgical rooms, critical areas and
Biosegurity L, are
designed for specific training on the Prevention and Control of Nosocomial
Infections and are particularly aimed at the Committees of the Infection
Control Hospital, Preventive Medicine, Managers and and Maintenance
Technicians,Safety and Risk assessment Services, Doctors and supervisors.
More details...
|
- DIAGNOSIS OF ASBESTOS IN
BUILDINGS

Where it is
expected that a building may contain asbestos, it must define a
methodology of diagnosis to follow.
Due to the
hazardous nature of asbestos work, it will require a thorough diagnosis and
the definition and adoption of a plan before any intervention.
|
|